Authors

Jawaad Sheriff

Type

Text

Type

Dissertation

Advisor

Mary D. Frame | Schwartz, Michael | Wadie F. Bahou.

Date

2010-12-01

Keywords

Biomedical Engineering | Activation, Damage Model, Platelet, Sensitization

Department

Department of Biomedical Engineering

Language

en_US

Source

This work is sponsored by the Stony Brook University Graduate School in compliance with the requirements for completion of degree.

Identifier

http://hdl.handle.net/11401/72670

Publisher

The Graduate School, Stony Brook University: Stony Brook, NY.

Format

application/pdf

Abstract

Increased shear stresses are a hallmark of flow conditions in blood recirculating devices, and patients implanted with such devices require lifelong anticoagulation to counteract the high risk of thromboembolism. Despite this limitation, manufacturers only test for hemolysis in order to optimize device design. This is primarily due to the paucity of data regarding platelet damage, a major precursor of thromboembolism. Several studies have shown that platelets exposed to constant shear stress for a specified duration become activated. However, post high-shear stress activation behavior of platelets, which is critical to understanding increased thrombotic risk associated with blood recirculating devices, is poorly understood.Purified platelets were briefly exposed to high shear stress followed by longer periods of low shear stress. Platelet activity state (PAS) was measured using a modified prothrombinase assay. Platelets subject to an initial shear stress of 60 dyne/cm2 and higher for 40 s showed minimal activation, but they exhibited a post-exposure activation rate that was significantly higher than for platelets that had not suffered the initial high shear insult. This sensitization response, although not significant, was also observed for platelets exposed to 1,000 dyne/cm2 for 25 ms, similar to conditions found in blood recirculating devices. Shear-induced platelet sensitization was amplified when platelets were pre-treated with biochemical agonists thrombin receptor activating peptide (TRAP) and collagen, and attenuated with the addition of apyrase. This indicates physiological modulation of platelet activation after pathological shear stress exposure.A model predicting platelet activation in response to shear stress, duration of exposure, and shear-loading rate was derived and optimized using in vitro sensitization results. These observations and predictive model may provide blood recirculating device manufacturers with a tool to optimize product design for minimizing platelet response and thromboembolic complications rather than hemolysis.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.